Description: The Embedded FBG strain gaugeis used to measure the change of strain inside concrete, it’s adopts a encapsulation structure to make the sensor itself and the concrete to achieve stiffness matching, to improve the embedding survival rate; It is suitable for monitor the strain of long-time embedded beam, column, pile foundation, support, retaining wall, hydraulic structure, lining, pier, base and foundation.;for the temperature is compensated by embedding a strain-free cylinder. |
Application:
Monitor Encapsulated structure Long-term / Short-Term Harsh Environments Monitor
Long-time Strain Monitoring of embedded beam, column, pile foundation, support, retaining wall, hydraulic structure, lining, pier, base and foundation.
Features:
●High precision, high stability, high reliability;
●Safe, anti-electromagnetic interference, corrosion resistance, pollution resistance, strong lightning resistance, can be used in strong electromagnetic interference, high lightning strike, flammable, easy explosion and other harsh conditions;
● Distance for transmission signal up to 40Km;
● Distributed measurement, multiple sensors connected on a single optical fiber (typical: 12)
● Simple layout, can be use together with other types of fiber grating sensor;
Technical specification:
Product Name | FBG Strain gauge | Temp Range | -40℃~80℃ |
Range | ±1500με | Installation | Surface welding/ Buried |
Resolution | <0.1%F.S. | Sensor lead wire | Left & Right (1m±0.1m) Armored Optical cable |
Accuracy | <0.3%F.S. | Connection Mode | Welding or FC/APC Joint |
Distance | 90mm | Central wavelength | 1525~1565nm |
Size | Φ28×120mm | Reflectivity | >85% |